York ZJ 180 to 300 Sunline Magnum Commercial Rooftop Units

  • Capacity: 15 – 25 Tons
  • Efficiency: 10.6 – 12.2 EER / 11.0 – 14.2 IEER
  • Warranty: Compressor – 5 year limited
  • Heat Exchanger – 10 year limited
  • Other parts – 1 year limited

FEATURES:

  • Meets or exceeds ASHRAE Standard 90.1 and is ENERGY STAR® qualified.
  • Smart Equipment—The new generation of UPG control is provided as a standard component on the Sunline™ packaged unit that provides the reliability and ease of use found in Smart Equipment.
  • Energy-efficient scroll compressors.
  • All model sizes share a common compact cabinet in a single footprint for on-site flexibility.
  • Installation time and costs are reduced by easy power and control wiring. All units are factory-wired,
    piped, charged and tested prior to shipment. Factory-installed options further reduce installation costs.
  • Gas and electric utility knockouts are provided on unit side and bottom for easy connections.
  • Convertible airflow design means no panel cutting is required and no accessory panel is necessary.
  • The wide range of indoor airflows achieved with belt-drive blowers.
  • The durable finish made of powder-painted, galvanized steel meets 1000-hour salt-spray test demands.
  • Full-perimeter base rails are permanently attached to provide a solid unit foundation.
  • The compressor is internally protected against high pressure and temperature.
  • Grooved copper tubes and enhanced aluminum-fin construction improve heat transfer.
  • Heat exchangers use corrosion-resistant, aluminized steel tubular construction for durability and long service life.
  • Permanently lubricated condenser and evaporator fan motor bearings need no annual maintenance.
  • Complete line of field-installed accessories, including propane and high-altitude conversion kits, stainless steel heat exchangers, motorized dampers, economizers, single- and dual-enthalpy sensors, powered convenience outlet and disconnect switch.
  • Constant (CV), multiple speed (IntelliSpeed™) and variable air volume (VAV) option featuring a variable frequency drive (VFD) is available in several different factory and field-installed configurations to accommodate zoning needs.
York ZJ 180 to 300 Sunline Magnum Commercial Rooftop Units was last modified: August 3rd, 2023 by HVAC Expert

Reviews

There are no reviews yet.

Be the first to review “York ZJ 180 to 300 Sunline Magnum Commercial Rooftop Units”

People like you shared their purchase and installation experience!

Michelle ZornMichelle Zorn

I had the most fabulous experience with Cozy Comfort Plus! Brian was very responsive for my first outreach all the way through to the completion of my beautiful fireplace! I live in a condo and as such, things are not straightforward when it comes to having work completed. There were a few extra hoops to jump through but Brian and his team were very diligent in ensuring that all the fittings were correct. I was so happy with my experience that I had them replace my furnace and add a smart home thermometer as well! I would highly recommend Brian and his team for their knowledge, skill and excellent customer service!

Read More
Jon ConwayJon Conway

We are so happy with the service, support and product that we received from Cozy Comfort Plus. Brian was incredible to work with, he took the time to understand what we were looking for and helped us with the designs and what the best fireplace for us might be. He is extremely easy to work with, very easy to communicate with and so fast and responsive!

Everything happened exactly on schedule and as planned. It was a well oiled machine!! The crews that were here to build everything were super friendly, kind, courteous and knowledgeable.

Highly highly recommend to all 😀👍

Read More
Andrew MunnAndrew Munn

Highly recommended. Brian at Cozy Comfort Plus supplied and installed 6 ductless heads on two compressors. The price was very competitive. The installation crew lead by Hamid did a perfect job. They explained the best locations for the equipment and answered all my questions. The work was completed a very short time after signing the contract. The team cleaned up the job site very carefully every night and were very careful indoorA.

Read More