Carrier Weathermaker – 48TC Commercial Rooftop Units

48TC WEATHERMAKER® rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, “no-strip screw” collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with environmentally sound Puron® (R-410A) refrigerant at the factory. The units are factory tested in both heating and cooling modes.

  • 3 to 27.5 Nominal Tons

 

Performance Features

  • ASHRAE 90.1 compliant
  • Up to 13.0 SEER, 11.8 IEER, and 11.1 EER
  • Gas efficiencies up to 82%
  • Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving
  • indoor fan motor delay
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • Belt drive evaporator-fan motor and pulley combinations available to meet any application
  • Two-inch disposable return air filters

Installation Features

Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time
Field convertible from vertical to horizontal airflow for slab mounting (sizes 04-16)
Provisions for thru-the-bottom power entry capability as standard
Dedicated vertical and horizontal airflow models available (sizes 17 to 30 only)
Single point gas, electric, and controls connections
Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Exclusive IGC anti-cycle protection for gas heat operation
  • Solid-state electronic direct spark ignition system and flame roll-out safety protector

Standard Limited Warranty

  • 10 years parts only heat exchanger – aluminized
  • 15 years parts only heat exchanger – stainless steel
  • 5 years parts only compressor
  • 3 years parts only on Novation™ condenser coil
  • One year parts only on all other parts
  • Extended warranty packages available
Carrier Weathermaker – 48TC Commercial Rooftop Units was last modified: August 3rd, 2023 by HVAC Expert

Reviews

There are no reviews yet.

Be the first to review “Carrier Weathermaker – 48TC Commercial Rooftop Units”

Factory-Installed Options

  • Cabinet
    • Thru-the-base electrical or gas-line connections
    • Hinged access panels
  • Coil Options
    • Cu/Cu indoor and/or outdoor coils
    • Pre-coated outdoor coils
    • Premium, E-coated outdoor coils
  • Humidity Control
    • Humidi-MiZer Adaptive dehumidification system (sizes 04-28 only)
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • PremierLink DDC communicating controller
    • RTU OPEN multi-protocol controller
    • Smoke detector (supply and/or return air)
  • Economizers & Outdoor Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper (sizes 17-30)
    • Barometric relief
    • Power exhaust (sizes 17-30)
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Single enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Indoor Motor & Drive
    • Multiple motor and drive packages
    • Staged Air Volume (SAV) Indoor Fan Speed System (sizes 08-30)
  • Power Options
    • Convenience outlet (powered)
    • Convenience outlet (unpowered)
    • Non-fused disconnect

Field-Installed Accessories

  • Cabinet
    • Thru-the-base electrical or gas-line connections
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • Thermostats, temperature sensors, and subbases
    • PremierLink DDC communicating controller
    • RTU OPEN multi-protocol controller
    • Smoke detector (supply and/or return air)(sizes 17-30)
    • Time Guard II compressor delay control circuit
    • Filter status switch
    • Fan status switch
  • Economizers & Outdoor Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper (sizes 17-30)
    • Barometric relief
    • Power exhaust(sizes 17-30)
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Differential dry bulb temperature sensors
    • Single enthalpy sensors
    • Differential enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Gas Heat
    • Liquid propane (LP) conversion kit
    • High altitude conversion kit
  • Low Ambient Control
    • Winter start kit
    • Motormaster head pressure controller
  • Roof Curbs
    • Roof curb 14″ (356mm)
    • Roof curb 24″ (610mm)

Data

Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in) LxWxH Low Gas Heating Input (MBtuh) Medium Gas Heating Input (MBtuh) High Gas Heating Input (MBtuh) Approx. Unit Weight (lbs)
3 1 (13.0) 74 x 47 x 33 72 115 483
4 1 (13.0) 74 x 47 x 33 72 115 150 537
5 1 (13.0) 74 x 47 x 33 72 115 150 569
6 1 11.0 74 x 47 x 41 72 125 150 652
7.5 1 11.0 88 x 59 x 41 125 180 224 780
7.5 2 11.0 88 x 59 x 41 125 180 224 835
8.5 1 11.0 88 x 59 x 49 125 180 224 920
8.5 2 11.0 88 x 59 x 49 125 180 224 930
10 1 11.0 88 x 59 x 49 180 224 250 930
10 2 11.1 88 x 59 x 49 180 224 250 940
12.5 2 10.8 88 x 59 x 49 150 180 240 1167
15 2 10.8 116 x 63 x 57 220 310 400 1380
15 2 10.8 128 x 87 x 49 220 310 400 1907
17.5 2 10.8 128 x 87 x 49 220 310 400 1922
20 2 9.8 141 x 87 x 49 220 310 400 2072
25 2 9.8 141 x 87 x 49 220 310 400 2197
27.5 2 10.2 158 x 87 x 57 220 310 400 2320

People like you shared their purchase and installation experience!

Nick SmidstraNick Smidstra

Brian and his team did a fantastic job replacing our tankless hot water heater for a fair price. Great work on a complicated job requiring new piping to be installed through our attic and roof. Would recommend this company to anyone!

Read More
Jon ConwayJon Conway

We are so happy with the service, support and product that we received from Cozy Comfort Plus. Brian was incredible to work with, he took the time to understand what we were looking for and helped us with the designs and what the best fireplace for us might be. He is extremely easy to work with, very easy to communicate with and so fast and responsive!

Everything happened exactly on schedule and as planned. It was a well oiled machine!! The crews that were here to build everything were super friendly, kind, courteous and knowledgeable.

Highly highly recommend to all 😀👍

Read More
Andrew MunnAndrew Munn

Highly recommended. Brian at Cozy Comfort Plus supplied and installed 6 ductless heads on two compressors. The price was very competitive. The installation crew lead by Hamid did a perfect job. They explained the best locations for the equipment and answered all my questions. The work was completed a very short time after signing the contract. The team cleaned up the job site very carefully every night and were very careful indoorA.

Read More