WeatherMaker® 50KCQ rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, “no-strip screw” collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with Puron (R-410A) refrigerant and are factory tested.

  • 3 to 5 Nominal Tons

Description

Performance Features

  • ASHRAE 90.1 compliant
  • Single-stage cooling capacity control
  • Up to 14.3 SEER, 12.2 EER and 8.2 HSPF
  • Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Direct Drive – ECM indoor fan motor standard with optional belt drive systems available
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as installed Carrier 3-5 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas, electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • Compressor crankcase heaters (sizes 05 to 06 sizes)
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Liquid line filter drier as standard

Standard Limited Warranty

  • 5 years parts only electric heater
  • 5 years parts only compressor
  • One year parts only on all other parts
  • Additional extended warranty packages available

Reviews

There are no reviews yet.

Be the first to review “Carrier Weathermaker – 50KCQ Commercial Rooftop Units”

Your email address will not be published. Required fields are marked *

Options

<table class="table table-striped table-condensed" border="0" cellspacing="0" cellpadding="0"> <tbody> <tr class="odd"> <td></td> <td><strong>Factory-Installed</strong></td> <td><strong>Field-Installed</strong></td> </tr> <tr> <td colspan="3"><strong>Cabinet</strong></td> </tr> <tr class="odd"> <td>Thru the base electrical or gas line connections</td> <td>X</td> <td>X</td> </tr> <tr> <td>Hinged access panels</td> <td>X</td> <td></td> </tr> <tr class="odd"> <td colspan="3"><strong>Coil Options</strong></td> </tr> <tr> <td>Cu/Cu indoor and/or outdoor coils</td> <td>X</td> <td></td> </tr> <tr class="odd"> <td>Pre-coated outdoor coils</td> <td>X</td> <td></td> </tr> <tr> <td>Premium, e-coated outdoor coils</td> <td>X</td> <td></td> </tr> <tr class="odd"> <td colspan="3"><strong>Condenser Protection</strong></td> </tr> <tr> <td>Condenser coil hail guard (louvered design)</td> <td>X</td> <td>X</td> </tr> <tr class="odd"> <td colspan="3"><strong>Controls</strong></td> </tr> <tr> <td>Thermostats, temperature sensors and subbases</td> <td></td> <td>X</td> </tr> <tr class="odd"> <td>PremierLink DDC communicating controller</td> <td>X</td> <td>X</td> </tr> <tr> <td>RTU Open multi-protocol controller</td> <td>X</td> <td>X</td> </tr> <tr class="odd"> <td>Smoke detector (supply and/or return air)</td> <td>X</td> <td></td> </tr> <tr> <td>Time Guard II compressor delay control circuit</td> <td></td> <td>X</td> </tr> <tr class="odd"> <td>Filter status switch</td> <td></td> <td>X</td> </tr> <tr> <td>Fan status switch</td> <td></td> <td>X</td> </tr> <tr class="odd"> <td colspan="3"><strong>Economizers & Outdoor Air Dampers</strong></td> </tr> <tr> <td>EconoMi$er IV (for electro-mechanical controlled RTUs)</td> <td>X</td> <td>X</td> </tr> <tr class="odd"> <td>EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)</td> <td>X</td> <td>X</td> </tr> <tr> <td>EconoMi$er 2 (for DDC controlled RTUs)</td> <td>X</td> <td>X</td> </tr> <tr class="odd"> <td>Ultra-low leak economizer dampers</td> <td>X</td> <td>X</td> </tr> <tr> <td>Motorized 2-position outdoor air damper</td> <td>X</td> <td>X</td> </tr> <tr class="odd"> <td>Manual outdoor dir damper</td> <td></td> <td>X</td> </tr> <tr> <td>Barometric relief</td> <td>X</td> <td>X</td> </tr> <tr class="odd"> <td>Power exhaust</td> <td></td> <td>X</td> </tr> <tr> <td colspan="3"><strong>Economizer Sensors & IAQ Devices</strong></td> </tr> <tr class="odd"> <td>Single dry bulb temperature sensors</td> <td>X</td> <td>X</td> </tr> <tr> <td>Differential dry bulb temperature sensors</td> <td></td> <td>X</td> </tr> <tr class="odd"> <td>Single enthalpy sensors</td> <td>X</td> <td>X</td> </tr> <tr> <td>Differential enthalpy sensors</td> <td></td> <td>X</td> </tr> <tr class="odd"> <td>CO2 sensor (wall, duct, or unit mounted)</td> <td>X</td> <td>X</td> </tr> <tr> <td colspan="3"><strong>Electric Heat</strong></td> </tr> <tr class="odd"> <td>Multiple electric resistance heater kW sizes</td> <td></td> <td>X</td> </tr> <tr> <td>Single point kit</td> <td></td> <td>X</td> </tr> <tr class="odd"> <td colspan="3"><strong>Indoor Motor & Drive</strong></td> </tr> <tr> <td>Multiple motor and drive packages</td> <td>X</td> <td></td> </tr> <tr class="odd"> <td colspan="3"><strong>Low Ambient Control</strong></td> </tr> <tr> <td>Winter start kit</td> <td></td> <td>X</td> </tr> <tr class="odd"> <td>Motormaster head pressure controller</td> <td></td> <td>X</td> </tr> <tr> <td colspan="3"><strong>Power Options</strong></td> </tr> <tr class="odd"> <td>Convenience outlet (powered)</td> <td>X</td> <td></td> </tr> <tr> <td>Convenience outlet (unpowered)</td> <td>X</td> <td></td> </tr> <tr class="odd"> <td>Non-fused disconnect</td> <td>X</td> <td></td> </tr> <tr> <td colspan="3"><strong>Roof Curbs</strong></td> </tr> <tr class="odd"> <td>Roof curb 14″ (356mm)</td> <td></td> <td>X</td> </tr> <tr> <td>Roof curb 24″ (610mm)</td> <td></td> <td>X</td> </tr> </tbody> </table>

People like you shared their purchase and installation experience!

[bne_testimonials custom="16159"]

Deprecated: trim(): Passing null to parameter #1 ($string) of type string is deprecated in /home/newcozyc/public_html/wp-content/plugins/simple-lightbox/includes/class.utilities.php on line 545