Carrier Weathermaker – 50TCQ Commercial Rooftop Units

WeatherMaker® 50TCQ rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, “no-strip screw” collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally sound Puron (R-410A) refrigerant and are factory tested.

  •  3 to 20 Nominal Tons

 

Description

Performance Features

  • ASHRAE 90.1 compliant
  • Single-stage capacity control (sizes 04 to 07)
  • Two-stage cooling capacity control (sizes 08 to 24)
  • Up to 13.4 SEER, 12.2 IEER, 11.2 EER, HSPF 7.7, and COP 3.4
  • Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Reviews

There are no reviews yet.

Be the first to review “Carrier Weathermaker – 50TCQ Commercial Rooftop Units”

Your email address will not be published. Required fields are marked *

Factory-Installed Options

<ul> <li>Cabinet <ul> <li>Thru-the-base electrical or gas-line connections</li> <li>Hinged access panels</li> </ul> </li> <li>Coil Options <ul> <li>Cu/Cu indoor and/or outdoor coils</li> <li>Pre-coated outdoor coils</li> <li>Premium, E-coated outdoor coils</li> </ul> </li> <li>Condenser Protection <ul> <li>Condenser coil hail guard (louvered design)</li> </ul> </li> <li>Controls <ul> <li>PremierLink DDC communicating controller</li> <li>RTU OPEN multi-protocol controller</li> <li>Smoke detector (supply and/or return air)</li> </ul> </li> <li>Economizers & Outdoor Air Dampers <ul> <li>EconoMi$er IV (for electro-mechanical controlled RTUs)</li> <li>EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)</li> <li>EconoMi$er2 (for DDC controlled RTUs)</li> <li>Ultra-low leak economizer dampers</li> <li>Motorized 2 position outdoor-air damper</li> <li>Manual outdoor-air damper (sizes 17-24)</li> <li>Barometric relief</li> <li>Power exhaust (sizes 17-24)</li> </ul> </li> <li>Economizer Sensors & IAQ Devices <ul> <li>Single dry bulb temperature sensors</li> <li>Single enthalpy sensors</li> <li>CO2 sensor (wall, duct, or unit mounted)</li> </ul> </li> <li>Indoor Motor & Drive <ul> <li>Multiple motor and drive packages</li> <li>Staged Air Volume (SAV) Indoor Fan Speed System (sizes 08-30)</li> </ul> </li> <li>Power Options <ul> <li>Convenience outlet (powered)</li> <li>Convenience outlet (unpowered)</li> <li>Non-fused disconnect</li> </ul> </li> </ul>

Field-Installed Accessories

<ul> <li>Cabinet <ul> <li>Thru-the-base electrical or gas-line connections</li> </ul> </li> <li>Condenser Protection <ul> <li>Condenser coil hail guard (louvered design)</li> </ul> </li> <li>Controls <ul> <li>Thermostats, temperature sensors, and subbases</li> <li>PremierLink DDC communicating controller</li> <li>RTU OPEN multi-protocol controller</li> <li>Smoke detector (supply and/or return air) (sizes 17-24)</li> <li>Time Guard II compressor delay control circuit</li> <li>Filter status switch</li> <li>Fan status switch</li> </ul> </li> <li>Economizers & Outdoor Air Dampers <ul> <li>EconoMi$er IV (for electro-mechanical controlled RTUs)</li> <li>EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)</li> <li>EconoMi$er2 (for DDC controlled RTUs)</li> <li>Ultra-low leak economizer dampers</li> <li>Motorized 2 position outdoor-air damper</li> <li>Manual outdoor-air damper</li> <li>Barometric relief</li> <li>Power exhaust</li> </ul> </li> <li>Economizer Sensors & IAQ Devices <ul> <li>Single dry bulb temperature sensors</li> <li>Differential dry bulb temperature sensors</li> <li>Single enthalpy sensors</li> <li>Differential enthalpy sensors</li> <li>CO2 sensor (wall, duct, or unit mounted)</li> </ul> </li> <li>Electric Heat <ul> <li>Multiple Electric Resistance Heater KW Sizes</li> <li>Single Point kit</li> </ul> </li> <li>Low Ambient Control <ul> <li>Winter start kit</li> <li>Motormaster head pressure controller</li> </ul> </li> <li>Roof Curbs <ul> <li>Roof curb 14″ (356mm)</li> <li>Roof curb 24″ (610mm)</li> </ul> </li> </ul>