Carrier Weathermaster – 50HC Commercial Rooftop Units

50HC WEATHERMASTER® rooftop unit were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, “no-strip screw” collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with environmentally sound Puron® (R-410A) refrigerant at the factory. The units are factory tested in cooling mode.

  • 3 to 25 Nominal Tons

Performance Features

  • ASHRAE 90.1 and Energy Star compliant
  • Up to 15.6 SEER, 13.0 IEER, and 12.2 EER
  • Standard cooling operating range up to 125 °F (52°C) and down to 35°F (-2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C)
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • TXV refrigerant metering device on each circuit with removable power element
  • Fully insulated cabinet

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles and tool-less filter access door
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Optional hinged access panels also available
  • Belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application
  • Electric Drive x13 (5 speed/torque) motor on 04 to 06 models
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as installed Carrier 3-5 and 7.5-10 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting (sizes 04 to 14)
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas and electric connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Dedicated vertical and horizontal airflow models available (factory option on size 17 to 28 units)

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Solid-state electronic direct spark ignition system and flame roll-out safety protector

Standard Limited Warranty

  • 10 years parts only electric heater
  • 5 years parts only compressor
  • One year parts only on all other parts
  • Extended warranty packages available

Reviews

There are no reviews yet.

Be the first to review “Carrier Weathermaster – 50HC Commercial Rooftop Units”

Factory-Installed Options

  • Cabinet
    • Thru-the-base electrical or gas-line connections
    • Hinged access panels
    • Foil-faced insulation
  • Coil Options
    • Cu/Cu indoor and/or outdoor coils
    • Pre-coated outdoor coils
    • Premium, E-coated outdoor coils
  • Humidity Control
    • Humidi-MiZer Adaptive dehumidification system
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • ComfortLink™ DDC communicating controller
    • PremierLink™ DDC communicating controller
    • RTU OPEN™ open-protocol controller
    • Smoke detector (supply and/or return air)
  • Energy Recovery
    • EnergyX® Factory Integrated Energy Recovery
  • Economizers & Outdoor
    • Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper (sizes 17-30)
    • Barometric relief
    • Power exhaust (sizes 17-30)
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Single enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Electric Heat
    • Multiple Electric Resistance Heater KW Sizes
    • Single Point kit
  • Indoor Motor & Drive
    • Multiple motor and drive packages
    • Staged Air Volume (SAV) Indoor Fan Speed System (sizes 08-28)
  • Low Ambient Control
    • Motormaster® head pressure controller
  • Power Options
    • Convenience outlet (powered)
    • Convenience outlet (unpowered)
    • Non-fused disconnect
    • HACR Circuit Breaker

Field-Installed Accessories

  • Cabinet
    • Thru-the-base electrical or gas-line connections
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • Thermostats, temperature sensors, and subbases
    • PremierLink™ DDC communicating controller
    • RTU OPEN™ open-protocol controller
    • Smoke detector (supply and/or return air) (sizes 17-30)
    • Time Guard II compressor delay control circuit
    • Filter status switch
    • Fan status switch
  • Economizers & Outdoor
    • Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper
    • Barometric relief
    • Power exhaust
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Differential dry bulb temperature sensors
    • Single enthalpy sensors
    • Differential enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Electric Heat
    • Multiple Electric Resistance Heater KW Sizes
    • Single Point kit
  • Low Ambient Control
    • Winter start kit
    • Motormaster® head pressure controller
  • Roof Curbs
    • Roof curb 14” (356mm)
    • Roof curb 24” (610mm)

Data

Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in) LxWxH Electric Heat Nominal Kilowatt Range Approx. Unit Weight (lbs)
3 1 (15.0) 74 x 47 x 33 4.0 to 16.0 458
4 1 (15.6) 74 x 47 x 41 4.4 to 23.0 545
5 1 (15.2) 74 x 47 x 41 6.5 to 26.5 550
6 1 12.2 88 x 59 x 41 6.0 to 26.5 715
7.5 2 12.2 88 x 59 x 49 10.0 to 42.4 860
8.5 2 12.2 88 x 59 x 49 10.4 to 42.4 860
10 2 12.0 88 x 59 x 49 10.0 to 51.0 865
10 2 11.7 88 x 59 x 49 10.0 to 51.0 865
12.5 2 12.4 116 x 63 x 57 15.0 to 51.0 1075
15 2 12.2 128 x 87 x 49 25.0 to 75.0 1093
17.5 2 12.2 141 x 87 x 49 25.0 to 75.0 1793
20 2 12.2 141 x 87 x 57 25.0 to 75.0 2148
25 2 11.4 158 x 87 x 57 25.0 to 75.0 2193