Carrier Weathermaster – 50HCQ Commercial Rooftop Units

WeatherMaster® 50HCQ rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, “no-strip screw” collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally sound Puron (R-410A) refrigerant and are factory tested.

  • 3 to 10 Nominal Tons

 

Description

Performance Features

  • ASHRAE 90.1 and Energy Star compliant
  • Single-stage capacity control (sizes 04 to 07)
  • Two-stage cooling capacity control (sizes 08 to 12)
  • Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP
  • Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) on size 04 to 14 units or down to 30°F (-1°C) on size 16 and 24 units
  • Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles and tool-less filter access door
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application
  • Electric Drive x13 (5 speed/torque) motor on 04 to 06 models
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as installed Carrier 3-10 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting (sizes 04 to 14)
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electric and control connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • Compressor crankcase heaters (sizes 05 to 12)
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Loss of charge, freeze protection, and high-pressure switches
  • Dependable time/temperature defrost board and logic

Standard Limited Warranty

  • 5-year parts only on electric heater
  • 5-years parts only compressor
  • 1-year parts only on other parts
  • Extended warranty packages available

Reviews

There are no reviews yet.

Be the first to review “Carrier Weathermaster – 50HCQ Commercial Rooftop Units”

Your email address will not be published. Required fields are marked *

Factory-Installed Options

<ul> <li>Cabinet <ul> <li>Thru-the-base electrical or gas-line connections</li> </ul> </li> <li>Coil Options <ul> <li>Cu/Cu indoor and/or outdoor coils</li> <li>Pre-coated outdoor coils</li> <li>Premium, E-coated outdoor coils</li> </ul> </li> <li>Condenser Protection <ul> <li>Condenser coil hail guard (louvered design)</li> </ul> </li> <li>Controls <ul> <li>PremierLink™ DDC communicating controller</li> <li>RTU OPEN™ open-protocol controller</li> <li>Smoke detector (supply and/or return air)</li> </ul> </li> <li>Economizers & Outdoor <ul> <li>EconoMi$er IV (for electro-mechanical controlled RTUs)</li> <li>EconoMi$er2 (for DDC controlled RTUs)</li> <li>Motorized 2 position outdoor-air damper</li> <li>Manual outdoor-air damper</li> <li>Barometric relief</li> <li>Power exhaust</li> </ul> </li> <li>Economizer Sensors & IAQ Devices <ul> <li>Single dry bulb temperature sensors</li> <li>Single enthalpy sensors</li> <li>Differential enthalpy sensor</li> <li>CO2 sensor (wall, duct, or unit mounted)</li> </ul> </li> <li>Indoor Motor & Drive <ul> <li>Multiple motor and drive packages</li> </ul> </li> <li>Power Options <ul> <li>Convenience outlet (powered)</li> <li>Convenience outlet (unpowered)</li> <li>Non-fused disconnect</li> </ul> </li> </ul>

Field-Installed Accessories

<ul> <li>Cabinet <ul> <li>Thru-the-base electrical or gas-line connections</li> </ul> </li> <li>Condenser Protection <ul> <li>Condenser coil hail guard (louvered design)</li> </ul> </li> <li>Controls <ul> <li>Thermostats, temperature sensors, and subbases</li> <li>PremierLink™ DDC communicating controller</li> <li>Smoke detector (supply and/or return air) (sizes 17-30)</li> <li>Time Guard II compressor delay control circuit</li> <li>Filter status switch</li> <li>Fan status switch</li> </ul> </li> <li>Economizers & Outdoor <ul> <li>EconoMi$er IV (for electro-mechanical controlled RTUs)</li> <li>EconoMi$er2 (for DDC controlled RTUs)</li> <li>Motorized 2 position outdoor-air damper</li> <li>Manual outdoor-air damper</li> <li>Barometric relief</li> <li>Power exhaust</li> </ul> </li> <li>Economizer Sensors & IAQ Devices <ul> <li>Single dry bulb temperature sensors</li> <li>Differential dry bulb temperature sensors</li> <li>Single enthalpy sensors</li> <li>Differential enthalpy sensors</li> <li>CO2 sensor (wall, duct, or unit mounted)</li> </ul> </li> <li>Low Ambient Control <ul> <li>Motormaster® head pressure controller</li> </ul> </li> <li>Roof Curbs <ul> <li>Roof curb 14” (356mm)</li> <li>Roof curb 24” (610mm)</li> </ul> </li> </ul>

Data

<table class="table table-striped table-condensed" border="0" cellspacing="0" cellpadding="0"> <thead> <tr class="headings odd"> <th class="first" rowspan="2">Nominal Cooling Ton Size</th> <th rowspan="2">Cooling Stages</th> <th rowspan="2">AHRI Efficiency (SEER) EER</th> <th rowspan="2">Dimensions (in) LxWxH</th> <th colspan="2">At 47°F</th> <th colspan="2">At 17°F</th> <th rowspan="2">Unit Weight (lbs)</th> </tr> <tr> <th>Heating Capacity (Btuh)</th> <th>(HSPF) COP</th> <th>Heating Capacity (Btuh)</th> <th>(HSPF) COP</th> </tr> </thead> <tbody> <tr class="odd"> <td>3</td> <td>1</td> <td>(15.6)</td> <td>74 x 47 x 33</td> <td>34000</td> <td>(8.00)</td> <td>18400</td> <td>(N/A)</td> <td>495</td> </tr> <tr> <td>4</td> <td>1</td> <td>(15.8)</td> <td>74 x 47 x 41</td> <td>46000</td> <td>(8.10)</td> <td>23800</td> <td>(N/A)</td> <td>580</td> </tr> <tr class="odd"> <td>5</td> <td>1</td> <td>(15.0)</td> <td>74 x 47 x 41</td> <td>55000</td> <td>(8.20)</td> <td>28600</td> <td>(N/A)</td> <td>610</td> </tr> <tr> <td>6</td> <td>1</td> <td>12.0</td> <td>88 x 59 x 41</td> <td>70000</td> <td>3.40</td> <td>39000</td> <td>2.40</td> <td>710</td> </tr> <tr class="odd"> <td>7.5</td> <td>2</td> <td>12.1</td> <td>88 x 59 x 49</td> <td>84600</td> <td>3.50</td> <td>47000</td> <td>2.40</td> <td>875</td> </tr> <tr> <td>8.5</td> <td>2</td> <td>12.0</td> <td>88 x 59 x 49</td> <td>100000</td> <td>3.40</td> <td>56000</td> <td>2.26</td> <td>1020</td> </tr> <tr class="odd"> <td>10</td> <td>2</td> <td>12.3</td> <td>116 x 63 x 57</td> <td>116000</td> <td>3.50</td> <td>65000</td> <td>2.40</td> <td>1390</td> </tr> </tbody> </table>

People like you shared their purchase and installation experience!

[bne_testimonials custom="16159"]

Deprecated: trim(): Passing null to parameter #1 ($string) of type string is deprecated in /home/newcozyc/public_html/wp-content/plugins/simple-lightbox/includes/class.utilities.php on line 545