Carrier Weathermaster – 50HCQ Commercial Rooftop Units

WeatherMaster® 50HCQ rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, “no-strip screw” collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally sound Puron (R-410A) refrigerant and are factory tested.

  • 3 to 10 Nominal Tons

 

Performance Features

  • ASHRAE 90.1 and Energy Star compliant
  • Single-stage capacity control (sizes 04 to 07)
  • Two-stage cooling capacity control (sizes 08 to 12)
  • Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP
  • Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) on size 04 to 14 units or down to 30°F (-1°C) on size 16 and 24 units
  • Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles and tool-less filter access door
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application
  • Electric Drive x13 (5 speed/torque) motor on 04 to 06 models
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as installed Carrier 3-10 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting (sizes 04 to 14)
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electric and control connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • Compressor crankcase heaters (sizes 05 to 12)
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Loss of charge, freeze protection, and high-pressure switches
  • Dependable time/temperature defrost board and logic

Standard Limited Warranty

  • 5-year parts only on electric heater
  • 5-years parts only compressor
  • 1-year parts only on other parts
  • Extended warranty packages available

Reviews

There are no reviews yet.

Be the first to review “Carrier Weathermaster – 50HCQ Commercial Rooftop Units”

Factory-Installed Options

  • Cabinet
    • Thru-the-base electrical or gas-line connections
  • Coil Options
    • Cu/Cu indoor and/or outdoor coils
    • Pre-coated outdoor coils
    • Premium, E-coated outdoor coils
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • PremierLink™ DDC communicating controller
    • RTU OPEN™ open-protocol controller
    • Smoke detector (supply and/or return air)
  • Economizers & Outdoor
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper
    • Barometric relief
    • Power exhaust
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Single enthalpy sensors
    • Differential enthalpy sensor
    • CO2 sensor (wall, duct, or unit mounted)
  • Indoor Motor & Drive
    • Multiple motor and drive packages
  • Power Options
    • Convenience outlet (powered)
    • Convenience outlet (unpowered)
    • Non-fused disconnect

Field-Installed Accessories

  • Cabinet
    • Thru-the-base electrical or gas-line connections
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • Thermostats, temperature sensors, and subbases
    • PremierLink™ DDC communicating controller
    • Smoke detector (supply and/or return air) (sizes 17-30)
    • Time Guard II compressor delay control circuit
    • Filter status switch
    • Fan status switch
  • Economizers & Outdoor
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper
    • Barometric relief
    • Power exhaust
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Differential dry bulb temperature sensors
    • Single enthalpy sensors
    • Differential enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Low Ambient Control
    • Motormaster® head pressure controller
  • Roof Curbs
    • Roof curb 14” (356mm)
    • Roof curb 24” (610mm)

Data

Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in) LxWxH At 47°F At 17°F Unit Weight (lbs)
Heating Capacity (Btuh) (HSPF) COP Heating Capacity (Btuh) (HSPF) COP
3 1 (15.6) 74 x 47 x 33 34000 (8.00) 18400 (N/A) 495
4 1 (15.8) 74 x 47 x 41 46000 (8.10) 23800 (N/A) 580
5 1 (15.0) 74 x 47 x 41 55000 (8.20) 28600 (N/A) 610
6 1 12.0 88 x 59 x 41 70000 3.40 39000 2.40 710
7.5 2 12.1 88 x 59 x 49 84600 3.50 47000 2.40 875
8.5 2 12.0 88 x 59 x 49 100000 3.40 56000 2.26 1020
10 2 12.3 116 x 63 x 57 116000 3.50 65000 2.40 1390

People like you shared their purchase and installation experience!