Carrier Weathermaster – 48P Commercial Rooftop Units

  • 48P2 – Vertical CV/SAV
  • 48P3 – Vertical VAV
  • 48P4 – Horizontal CV/SAV
  • 48P5 – Horizontal VAV
    Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial grade cabinet with fully hinged access panels. Forward-curved supply fans provide the performance of up to 4 in. external static pressure (ESP) and 6 in. ESP with optional airfoil supply fans.
    Units are available in the constant volume (CV), staged air volume (SAV), or variable air volume (VAV) applications, with a wide variety of gas heating options. Units come with the ComfortLink™ DDC (direct digital control) control system, scroll compressors on independent thermostatic expansion valve (TXV) controlled refrigeration circuits.
  • 30 to 100 Nominal Tons

Description

Performance Features

  • Multiple high-efficiency scroll compressors include a crankcase heater and vibration isolation
  • Up to 8 steps of cooling capacity control with intertwined evaporator coils for full-face active operation at part-load conditions
  • Cooling operating range from 32 to 115 F ambient (down to -20 F with accessory Motormaster® V control)
  • ComfortLink™ control includes: easy to use scrolling marquee display, service diagnostics, run test capabilities, demand limit
  • capability, compressor reverse rotation protection, and BACnet communication option.
  • Tested in accordance with UL Standard 1995 and listed by ETL and ETL, Canada
  • Meet or exceed the EER requirements of ASHRAE Standard 90.1, rated in accordance with ARI Standard 340/360
  • California Energy Commission Title 24 Compliant

Reliability Features

  • Dual electrically and mechanically independent refrigerant circuits, with coil frost protection, liquid line filter driers, and crankcase
  • heaters standard on all models
  • Compressor protection includes high and low-pressure transducers with safety cutouts
  • Circuit breaker protection for all power components
  • Cabinet made of pre-painted, galvanized steel with baked enamel finish, which meets ASTM B117 salt spray resistance test
  • Condenser-fan motors are totally enclosed with internal protection
  • Direct spark ignition, Alumagard Coated Turbo-tubular heat exchangers, and induced draft combination provide for safety and
  • reliability
  • Reliable Integrated Gas Unit Controller (IGC) provides system evaluation & troubleshooting via onboard LED and two-stage gas
  • valves with redundant 100% shutoff

Maintenance Features

  • Large hinged service access doors
  • Onboard diagnostics include refrigerant pressure sensors
  • Double wall design available

Installation Features

  • Shipped with R-410A refrigerant charge
  • Single point electrical service entry, through unit bottom or side
  • Lifting Lugs
  • Factory-installed pivoting outside air hoods

Standard Limited Warranty

  • 3 years parts only on Novation™ condenser coil
  • 5 years parts only, non-pro-rated, on the heat exchanger
  • One year parts only on all other parts

Reviews

There are no reviews yet.

Be the first to review “Carrier Weathermaster – 48P Commercial Rooftop Units”

Your email address will not be published. Required fields are marked *

Factory-Installed Options

<ul> <li>Low or high gas heat options include: <ul> <li>Aluminized steel heat exchanger</li> <li>Stainless steel heat exchanger</li> <li>Stainless steel heat exchanger with staged gas discharge air temperature control</li> <li>Stainless steel heat exchanger with modulating gas discharge air temperature control</li> </ul> </li> <li>Extended chassis for an auxiliary coil</li> <li>Double wall construction</li> <li>2-in. pleated filters with 4-in. field convertible filter rack</li> <li>Bag or cartridge filters (sizes 030-070 only)</li> <li>Outdoor air CFM station</li> <li>Manual outside air self-closing damper</li> <li>Modulating integrated economizer damper</li> <li>Modulating integrated ultra-low leak economizer damper</li> <li>Barometric relief</li> <li>Non-modulating power exhaust (CV units only)</li> <li>Modulating power exhaust with building pressure sensor</li> <li>Alternate high-capacity evaporator coil (all sizes except 035)</li> <li>High capacity power exhaust with VFD (sizes 075-100 only)</li> <li>Return fan with VFD (sizes 075-100 only)</li> <li>Condenser and evaporator options include: <ul> <li>All-aluminum Novation condenser and Al/Cu evaporator</li> <li>E-coat all-aluminum Novation condenser and Al/Cu evaporator</li> </ul> </li> <li>Hot gas bypass</li> <li>Controls input expansion board</li> <li>Bypass on indoor fan motor VFD</li> <li>GFI (ground fault interrupter) convenience outlet (powered)</li> <li>Power terminal block</li> <li>Non-fused disconnect</li> <li>Airfoil supply fan (sizes 075-100 only)</li> <li>Low outdoor sound</li> <li>Low ambient control</li> <li>65 kA SCCR (460V) or 25 kA SCCR (575V)</li> <li>Digital compressor</li> <li>BACnet communication</li> <li>Replaceable core filter drier</li> <li>Security grille (sizes 070-100 only)</li> <li>Humidi-MiZer™ adaptive dehumidification system</li> </ul>

Field-Installed Accessories

<ul> <li>Liquid propane (LP) conversion kit (sizes 030-070 only)</li> <li>2-in. and 4-in. filter kits</li> <li>CO2 space sensor</li> <li>Outdoor or return humidity sensor (enthalpy)</li> <li>Condenser coil hail guard assembly</li> <li>Controls input expansion board</li> <li>Navigator™ display</li> <li>Return air CO2 sensor</li> <li>Smoke detector</li> <li>Filter switch</li> <li>Fan status switch</li> <li>T55 temperature sensor</li> <li>T56 temperature sensor</li> <li>Space temperature sensor with CO2 override</li> <li>Space temperature sensor set point and CO2 override</li> <li>BACnet Communication module</li> <li>MODBUS Carrier translator</li> <li>LonWorks Carrier translator</li> <li>System Pilot™ interface</li> <li>Touch Pilot™ interface</li> <li>14-in. roof curb</li> <li>Motormaster V control</li> <li>Compressor sound blankets</li> </ul>

People like you shared their purchase and installation experience!